Enzyme Lab Report-- How do Different Temperatures Affect Enzyme Growth Rate?

How do Different Temperatures Affect Enzyme Growth Rate?
Cole Nelson, Claudia Bonenberger, Catie Missey, Andres Quintero
Period 01


Our lab provided data that supports the fact that reactions of enzymes are affected by temperature. Through grinding the grass into a liquid and combining it with hydrogen peroxide, the mixtures began to bubble then foam. To test temperature, we used graduated cylinders full of ice water, and microwaved water. The experiment showed that the reactions were sped up in the heated container, and slowed down in the iced container.

Introduction: (include background information) Enzymes can be affected by a number of things-- pH level, enzyme concentration, substrate concentration, and the presence of any inhibitors or activators. In this lab, we are observing the way different temperatures affect the rate enzymes work. Research shows that many enzymes will become less efficient, or even denature, in extreme temperatures. However, enzymes will not denature in cold temperatures, only in hot temperatures. Hot temperatures will change the active site which would result in complete denaturing. In our lab, we tested the rate of enzymes working at 5 degrees Celsius, at room temperature (about 23 degrees Celsius), and at 60 degrees Celcius. Enzymes slow at cooler temperatures not because their active site is being altered, but because the substrate molecules have less and less energy, therefore moving slower towards the enzyme. We hope to see a difference in results between the room temperature enzymes and the enzymes that were placed in the extreme temperatures.

Materials:
  1. 5 to 10 grams of freshly picked ripgut brome grass (Bromus diandrus) blades (about 1 handful)
  2. Digital balance (scale)
  3. Mortar and pestle
  4. Distilled water
  5. 3 100-liter glass or plastic beakers
  6. 1 mL or 5 mL syringe
  7. Hydrogen peroxide
  8. 1 Paper towel square (for filtration)
  9. Glass test tubes
  10. Test tube rack or holder
  11. Small plastic ruler
  12. Safety glasses
  13. Ice
  14. Large plastic beaker (2) for ice and hot bath
  15. Thermometer
  16. Stopwatch

Procedure:
  1. Measure out between 5 and 10 grams of grass (approx. 1 handful), and grind it with the mortar and pestle.
  2. Once all your grass has been grinded up, measure out how much of the grass concentrated liquid was grinded up, and pour it into the small graduated cylinder all through a syringe.
  3. Place the concentrated grass liquid into three different test tubes equally.
  4. Measure temperature of both the hot bath and the cold bath. Record temperatures.
  5. Place one test tube in the hot bath and one test tube in the cold bath. Leave one test tube without water (room temperature).
  6. Add the desired amount of hydrogen peroxide (same concentration, same amount). We used 1 mL of hydrogen peroxide.
  7. Watch and record reaction
  8. Keep track and measure how much change is happening to the solution in the graduated cylinder.

Results: (Trial 1-3 were pre-trial tests)
Trial 1
We started with 7.09 grams of grass for our initial trial. Once the grass concentrate was made, we separated it into a different container and used the syringe to equally put the grass liquid and the hydrogen peroxide into the test tube. 1 mL of grass liquid and 1 mL of hydrogen. After 5 minutes, the first trial did not change so we started a second with 1 ml of grass liquid and 3 ml of hydrogen peroxide. After 7 minutes and 8 seconds for the first timer, the test tube started to bubble. Besides from the initial bubbles, the solutions did not foam or show any signs of a reaction. We believed that the concentration was contaminated because the color was a dingy brownish green.  After 30 minutes, the solution began to bubble, and the color turned a light green and was more transparent.

Trial 2
This trial was the same measurements as the first, except instead of 1 mL of hydrogen peroxide, we added 3 mL. The second trial started at 1 minute 10 seconds. Besides from the initial bubbles, the solutions did not foam or show any signs of a reaction, just like the first trial. We came to the conclusion that this one was contaminated as well. We decided to switch up the mortar and pestle. After roughly 25 minutes, the solution started to bubble more and became a more transparent, light green color.

Trial 3
For trial three we wanted to make sure we had uncontaminated materials, so we changed the hydrogen peroxide and the mortar and pestle. We kept the same amount of grass (7.09 grams) and used 1 ml of hydrogen peroxide, and 1 ml of the grass liquid in the test tube. This solution began to bubble at a quicker rate, but it isn’t a fast rate either. At 25 minutes the foam was at 12 ml.

Main Trial
To compare our results we used trial 3. The foam for trial three was growing at a normal rate, at 10 minutes the foam was 6 ml high, and at 15 minutes, it was at 9 ml. We ended the timer at 25 minutes; the foam was at 12 ml.

The ice bath was 200 mL, and the water temperature was 6 degrees celsius.
At the timer's start, the test tube was submerged, the bubbles were only around the edges of the the test tube in the ice, so at about 2 mL. At ten minutes, the top of the solution was covered in bubbles. By fifteen minutes, the foam did not change, and it did not change throughout the rest of the time. The final volume of the bubbles was 3 mL.

The hot bath was 200 mL, and the water temperature was at 55 degrees celsius. At 30 seconds the top of the mixture started to bubble. At a minute, the mixture was fully separated. At 2 minutes 30 seconds the mixture was foaming slightly. At 6 minutes only bubbles had formed on the sides of test tube under water, the mixture had not changed. 10 minutes later, the mixture was a slightly transparent green, with a thick green layer on top. The mixture did not foam any more. We decided to stop this trial at fifteen minutes, seeing no further changes.

Bath type
Room temperature
Ice bath (6 C)
Hot bath (55 C)
Start time (0:00)
0 mL
0 mL
0 mL
10:00
6 mL
2 mL
1 mL
End time (15:00)
9 mL
3 mL
2 mL


Discussion: Despite having struggles with our test run trials, the real lab itself gave data that enzymes function worse in extreme temperatures than a room temperature surrounding. Enzymes in extreme cold (our ice bath), will slow down because there is no heat energy that they are able to consume. They then will work slower and slower, but they can not denature. Cold temperatures do not alter the enzyme’s active site, but merely strip them of all of their energy. If the temperature is increased, then the enzymes will be able to function again. Unlike the colder temperatures, hot temperatures can denature an enzyme. The high heat will affect the pH level, which will ultimately alter the active site. Our lab results did show that these statements are true, but in order to be certain, one would need to conduct and observe many more trials of enzymes under extreme temperatures.

Conclusion: Our main trial falls in line with the fact that enzymes will function slower at more extreme temperatures and will speed up their rates at a more optimal and ideal temperature. Although at very high temperatures, most enzymes will denature, our enzymes did not denature but instead worked increasingly slower and slower. The reasoning behind this is that the enzyme had too much energy and was slowly beginning to denature, but would have needed to be exposed to that extreme heat for a longer period of time.